High-end technologies are utilized to make Integrated UPS Power Cabinet 6KVA manufacturing process efficient and labor-saving. It has been found to be very useful in the field(s) of Other Power Supplies.
Keeping close up with the latest trend, Beijing Changfeng Innovation Technology Co., Ltd. has made Integrated UPS Power Cabinet 6KVA a competitive product in the market. It is expected to lead the industry trend and bring benefits to customers. Continuous innovation ability is the fundamental guarantee of product quality. Beijing Changfeng Innovation Technology Co., Ltd. will strive toward excellence by building our working principles of guaranteeing quality for survival and seeking innovation for development, into everything we deliver. We are confident that we will overcome all the difficulties and obstacles to make a success in the end.
Place of Origin: | Beijing, China | Brand Name: | CFINV |
Model Number: | 6KVA | Input Voltage: | 176vac ~ 275VAC |
Output Voltage: | 220Vac | Output Power: | 5400W |
Output Frequency: | 50 / 60 ± 10% | Output Current: | 24.5A |
Product Keyword: | Integrated distribution box | Capacity: | 6KVA |
Battery capacity: | 12V/24AH |
Commodity weight: 200kg
Package size: length * width * height: 610 * 810 * 2010
Packing list: one cabinet, one set of 6kV UPS, four battery packs, one 60A switching power supply and one set of cables
Article No.: xl-380v / 400a-02
Specification:
1. Input characteristics: voltage range (V): 176vac ~ 275VAC, with full load; 80vac ~ 176vac load capacity is linearly derated according to the input voltage amplitude; Frequency range (Hz) 50 / 60 ± 10% (50 / 60 adaptive); Input mode: single phase three wire; Battery voltage (V) 192 (default) (12 ~ 20 * 12V can be set for communication)
2. Output characteristics: capacity (VA / W) 6000 / 5400 ,10000 / 9000; Voltage (V) 220 ± 2% (default) (208 / 220 / 230 / 240 can be set); Frequency (Hz) 50 / 60 ± 0.2% (battery mode); Waveform sine wave voltage distortion thd < 1% (linear load), thd < 4% (nonlinear load); Power factor: 0.9 (1.0 at room temperature can be loaded for a long time) Switching time (MS): 0
3. AC input: single phase three wire system
Voltage range: 90-300v (175-275v RRC)
Frequency range: 45-66 Hz
Scale: 1 ø 220V, 50 / 60Hz
Protection: overload and short circuit protection
Lightning protection: Class C lightning protection and alarm: 385v 15 ~ 20KA (8 / 20) μ S)
4. DC output: 43.2 ~ 58V output shunt overload and short circuit protection; Any MCB fault will automatically generate audible and visual alarm
Shunting default configuration: load shunting: 4 * 32A